Volt

 
Model
Measurement Range
Resolution
Accuracy

Vrms (AC + DC)
434-II
1 V to 1000 V phase to neutral
0.1 V
±0.1% of nominal voltage1

435-II
1 V to 1000 V phase to neutral
0.01 V
±0.1% of nominal voltage1

Vpk
1 Vpk to 1400 Vpk
1 V
5% of nominal voltage

Voltage Crest Factor (CF)
1.0 > 2.8
0.01
±5%

Vrms½
434-II
1 V to 1000 V phase to neutral
0.1 V
± 1 % of nominal voltage

434-II and 435-II
 
0.1 V
±0.2% of nominal voltage

Vfund
434-II
1 V to 1000 V phase to neutral
0.1 V
± 0.5 % of nominal voltage

435-II
 
0.1 V
± 0.1 % of nominal voltage

Amps (accuracy excluding clamp accuracy)

Amps (AC + DC)
i430-Flex 1x 
5 A to 6000 A
1 A
±0.5% ±5 counts

i430-Flex 10x
0.5 A to 600 A
0.1 A
±0.5% ±5 counts

1mV/A 1x
5 A to 2000 A
1A
±0.5% ±5 counts

1mV/A 10x
0.5 A A to 200 A (AC only)
0.1 A
±0.5% ±5 counts

Apk
i430-Flex
8400 Apk
1 Arms
±5%

1mV/A
5500 Apk
1 Arms
±5%

A Crest Factor (CF)
1 to 10
0.01
±5%

Amps½
i430-Flex 1x
5 A to 6000 A
1 A
±1% ±10 counts

i430-Flex 10x
0.5 A to 600 A
0.1 A
±1% ±10 counts

1mV/A 1x
5 A to 2000 A
1 A
±1% ±10 counts

1mV/A 10x
0.5 A A to 200 A (AC only)
0.1 A
±1% ±10 counts

Afund
i430-Flex 1x
5 A to 6000 A
1 A
±0.5% ±5 counts

i430-Flex 10x
0.5 A to 600 A
0.1 A
±0.5% ±5 counts

1mV/A 1x
5 A to 2000 A
1 A
±0.5% ±5 counts

1mV/A 10x
0.5 A A to 200 A (AC only)
0.1 A
±0.5% ±5 counts

Hz

Hz
Fluke 434 @ 50 Hz Nominal
42.50 Hz to 57.50 Hz
0.01 Hz
±0.01 Hz

Fluke 434 @ 60 Hz Nominal
51.00 Hz to 69.00 Hz
0.01 Hz
±0.01 Hz

Fluke 435 @ 50 Hz Nominal
42.500 Hz to 57.500 Hz
0.001 Hz
±0.01 Hz

Fluke 435 @ 60 Hz Nominal
51.00 Hz to 69.00 Hz
0.001 Hz
±0.01 Hz

Power

Watts (VA, var)
i430-Flex
max 6000 MW
0.1 W to 1 MW
±1% ±10 counts

1 mV/A
max 2000 MW
0.1 W to 1 MW
±1% ±10 counts

Power Factor (Cos j/DPF)
0 to 1
0.001
±0.1% @ nominal load conditions

Energy

kWh (kVAh, kvarh)
i430-Flex 10x
Depends on clamp scaling and V nominal
±1% ±10 counts

Energy Loss
i430-Flex 10x
Depends on clamp scaling and V nominal
±1% ±10 counts Excluding line resistance accuracy

Harmonics

Harmonic Order (n)
DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7

Inter-Harmonic Order (n)
OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7

Volts %
f
0.0% to 100%
0.1%
±0.1% ±n x 0.1%

r
0.0% to 100%
0.1%
±0.1% ±n x 0.4%

Absolute
0.0 to 1000 V
0.1 V
±5%1

THD
0.0% to 100%
0.1%
±2.5%

Amps %
f
0.0% to 100%
0.1%
±0.1% ±n x 0.1%

r
0.0% to 100%
0.1%
±0.1% ±n x 0.4%

Absolute
0.0 to 600 A
0.1 A
±5% ±5 counts

THD
0.0% to 100%
0.1%
±2.5%

Watts %
f or r
0.0% to 100%
0.1%
±n x 2%

Absolute
Depends on clamp scaling and V nominal

±5% ±n x 2% ±10 counts

THD
0.0% to 100%
0.1%
±5%

Phase Angle
-360° to +0°

±n x 1°

Flicker

Plt, Pst, Pst (1 min) Pinst
0.00 to 20.00
0.01
±5%

Unbalance

Volts %
0.0% to 20.0%
0.1%
±0.1%

Amps %
0.0% to 20.0%
0.1%
±1%

Mains Signaling

Threshold Levels
Threshold, limits and signaling duration is programable for two signaling frequencies

Signaling Frequency
60 Hz to 3000 Hz
0.1 Hz
 

Relative V %
0% to 100%
0.10%
±0.4%

Absolute V3s (3 second avg.)
0.0 V to 1000 V
0.1 V
±5% of nominal voltage

General Specifications

Case
Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2

Display
Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated

Memory
8GB SD card (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).

Real-Time Clock
Time and date stamp for Trend mode, Transient display, System Monitor and event capture

Environmental

Operating Temperature
0°C ~ +40°C; +40°C ~ +50°C excl. battery

Storage Temperature
-20°C ~ +60°C

Humidity
+10°C ~ +30°C: 95% RH non-condensing
+30°C ~ +40°C: 75% RH non-condensing
+40°C ~ +50°C: 45% RH non-condensing

Maximum Operating Altitude
Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)

Electro-Magnetic-Compatibility (EMC)
EN 61326 (2005-12) for emission and immunity

Interfaces
Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery

Warranty
Three years (parts and labor) on main instrument, one year on accessories

1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if < 1% of nominal voltage
2. 50Hz/60Hz nominal frequency according to IEC 61000-4-30
3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode
4. For nominal voltage 50 V to 500 V